174610.00,DRIVE,LEESON,DRIVE,2HP 230V 1/3PH

174610.00,DRIVE,LEESON,DRIVE,2HP 230V 1/3PH

1.00 $

174610.00,DRIVE

MANUEL
pdf 174610.00

The SM2 SERIES FLUX VECTOR carries all the features required by demanding applications including four modes of operation (V/Hz, Enhanced V/Hz, Vector Speed, and Torque), High starting torque, auto-tuning, advanced low-speed control, and dynamic speed regulation.

  • Enclosure: NEMA1, IP21, -10 to 55*C, 2.5% derate per *C above 40*C
  • Standard Features: Easy Set-up and Operation: Program the Vector control in one of four convenient ways:

From the front of the drive 174610.00

    • The optional remote keypad
    • A PC Using TechLink Software
    • The innovative EPM Programmer.
  • Modes of operation:
    • Open Loop Flux Vector (Speed or Torque)
    • V/Hz (constant or variable)
    • Enhanced V/Hz with Auto-tuning
  • Easy to Use Keypad & Display 6-Button Interface:
    • Start
    • Stop
    • Forward/Reverse
    • Scroll Up
    • Scroll Down
    • Enter/Mode
  • Vivid Illumination:
    • 4 digit LED display
    • Easy to read from a distance
    • Movable Decimal Point
  • Acceleration/Deceleration Profiles:
    • Two Independent Accel Ramps
    • Two Independent Decel Ramps
    • Linear or S-Type
    • Auxiliary Ramp-to-Stop
  • Output Frequency:
    • 500 Hz Std., 1000 Hz Optional
  • Selectable Logic Assertion:
    • Positive Logic Input (PNP current sourcing)
    • Negative Logic Input (NPN current sinking)
  • Multiple Braking Functions
  • Loss of Follower Management
  • Speed Commands: Keypad, Jog, Floating Point Control
  • Voltage: Scalable 0-10 VDC
  • Current: Scalable 4-20mA, Potentiometer, 8 Preset Speeds
  • Process Control: PID Modes: Direct or Reverse Acting, PID Sleep Mode
  • Voltage Monitoring
  • Current Monitoring
  • Real Time Monitoring: 8 register fault history, Software Version Drive Network ID, DC Bus Voltage (V), Motor Voltage (V), Output Current (%) Motor Current (A), Motor Torque (%), Power (kW) Energy Consumption (kWh), Heasink Temperature (*C), 0-10 VDC Input (User Defined, 4-20 mA Input (User Defined) PID Feedback (User Defined), Analog Output (% Load, % Torque, kW), Network Speed (baud rate), Terminal Continuity, Keypad Status, Elapse Run Time (hours), Elapsed Power on Time (hours)
  • Standards:
    • UL (USA)
    • cUL (Canada)
    • CE (Europe)
    • GOST (Russia/Ukraine)
    • C-Tick (Australia/New Zealand)
  • Dimensions H x W x D (inches)   7.5 x 3.9 x 5.45

 

Need Help? Contact Us Leave Feedback

Share